Search the VMware Knowledge Base (KB)
View by Article ID

Outstanding IO Requests Setting is not persistent after reboot of ESXi (2150431)

  • 0 Ratings

Symptoms

  • The ESXi storage device settings are not restored after the reboot of the corresponding LUNs presented from EMC ScaleIO.

    For example Maximum Outstanding Disk Requests(DSNRO), Queue Full Sample Size, Queue Full Threshold.

Cause

In the ESXi, LUNs are discovered and settings are applied to corresponding devices during boot. But in case EMC ScaleIO discovery of LUNs is not guaranteed to happen during boot which might lead to not restoring the previous setting for the storage device.

Resolution

To workaround the issue, use the following command after ESXi reboot:

#localcli --plugin-dir /usr/lib/vmware/esxcli/int/ boot storage restore --paths

Request a Product Feature

To request a new product feature or to provide feedback on a VMware product, please visit the Request a Product Feature page.

Feedback

  • 0 Ratings

Did this article help you?
This article resolved my issue.
This article did not resolve my issue.
This article helped but additional information was required to resolve my issue.

What can we do to improve this information? (4000 or fewer characters)




Please enter the Captcha code before clicking Submit.
  • 0 Ratings
Actions