The available workarounds depend upon whether or not a pre-upgrade snapshot is available.
Note: Snapshots should always be taken before any significant change or upgrade.
touch /var/log/bootstrap/fips_disable
chmod 644 /var/log/bootstrap/fips_disable
Note: You may run these steps before any upgrade attempt to prevent this issue from occurring.
In such cases when after the upgrade the UI shows no details of the upgraded version, these are the steps to fix the appliance.
/etc/bootstrap/postupdate.d/26-cleanup-pspak-db-backups && /etc/bootstrap/postupdate.d/27-fill-cap-product-info && /etc/bootstrap/postupdate.d/60-update-upgrade-status && /etc/bootstrap/postupdate.d/70-blackstone-upgrade.sh && /etc/bootstrap/postupdate.d/80-cleanup-patch-history && /etc/bootstrap/postupdate.d/90-enable-fips-mode && /etc/bootstrap/postupdate.d/91-create-cap-update-settings && /etc/bootstrap/postupdate.d/92-disable-vami-lighttpd
systemctl restart cap-workflow-engine.service
{"state":"UP_TO_DATE","version":"","latest_query_time":"<do-not-change-the-value>","instance_id":"<do-not-change-the-value>","current_workflow":"cap-non-lvm-update","progress":"100%","message":"Completed","status":"Completed"}
Note: The entry should be similar to:
Upgrade Completed Successfully from 8.2.0.23 to 8.10.0.6 on 1665243746
Upgrade Completed Successfully from 8.10.0.6 to 8.12.0.7 on 1687777307
Upgrade Completed Successfully from to on 1697732933
Upgrade Completed Successfully from 8.2.0.23 to 8.10.0.6 on 1665243746
Upgrade Completed Successfully from 8.10.0.6 to 8.12.0.7 on 1687777307
Upgrade Completed Successfully from 8.12.0.7 to 8.14.0.4 on 1697732933
{ "product_name": "VMware Aria Suite Lifecycle Appliance", "version": "8.14.0.4", "build_number": "22630472" }
/etc/bootstrap/postupdate.d/99-reboot-va