"Failed waiting for data. Error 195887179" when attempting to vMotion
search cancel

"Failed waiting for data. Error 195887179" when attempting to vMotion

book

Article ID: 318797

calendar_today

Updated On:

Products

VMware vSphere ESXi

Issue/Introduction





Symptoms:
  • vMotion fails with the error : 
Failed waiting for data. Error 195887179.Connection reset by peer.
Failed waiting for data. Error 195887179.Connection reset by peer.
  • You may also see an error similar to:
Failed waiting for data. Error 195887371....
 
  • In the /var/log/vmkernel.log file, you see the error:

    vMotion vmknic is undefined.vMotion will attempt to proceed, but may not reach optimal performance.

Note: This can prevent a host from going into maintenance mode due to running virtual machines.


Environment

VMware vSphere ESXi 6.7
VMware vSphere ESXi 6.5
VMware vSphere ESXi 6.0
VMware vSphere ESXi 7.0.0

Cause

This issue occurs if there is a mismatch between the Jumbo frame size in the physical network and the vmkernel MTU settings.
 
Possible mismatch of the Jumbo frame size between vmkernel and physical network MTU settings are:
  • MTU 9000 (Jumbo) in the vmkernel
  • MTU 8982  or 1500 in the physical network interface.

Resolution

To resolve this issue, change the (vMotion) vmkernel MTU size to match the physical network interface.

Note: When dealing with MTU issues, ensure every interface in the packet path is using the same MTU value. For example, this issue can occur when the vMotion vSwitch has a different MTU than the vMotion vmkernel port.

For information on changing the MTU size for a Standard Switch, see Change the Size of the MTU on a vSphere Standard Switch

Workaround:
You can perform the following solution as a workaround or troubleshooting step until you check physical network MTU size:
  • Edit vMotion vmkernel and add default value 1500 instead of jumbo frames.
Note: It is still recommended that you set every interface in the packet path to the exact same MTU value (vmkernel and physical interface).


Additional Information

iSCSI and Jumbo Frames configuration on VMware ESXi/ESX
VMware ESXi 6.x にアップグレードすると vMotion がエラー「Failed waiting for data. Error 195887179. Connection reset by peer」で失敗する
在 ESXi 6.x 中,vMotion 失败并出现错误“等待数据失败。 错误 195887179。 连接由对等重置”