This is a known issue affecting VMware vRealize Automation 7.3.0.
This issue is resolved in VMware vRealize Automation 7.3.1 and vRealize Automation 7.4, available at
VMware Downloads.
Workaround:
To work around this issue in VMware vRealize Automation 7.3.0,
- Log in to the primary IaaS Model Manager Windows machine.
Note:The primary IaaS Model Manager Windows machine is the machine that has the C:\Program Files (x86)\VMware\vCAC\Server\Model Manager Data folder.
- Open command prompt in Administrator mode.
- Run these commands in the same order:
- cd C:\Program Files (x86)\VMware\vCAC\Server\Model Manager Data\Cafe
- vcac-config.exe RegisterCatalogTypesAsync -v
- vcac-config.exe UpgradeEndpoints -v
Now the endpoints should be visible under Endpoints page of the Infrastructure tab.
Note: If you had manually re-created endpoints and now see duplicate endpoints, then contact VMware Support to remove the newly added endpoints and note this KB article ID (2150252) in the problem description. For more information, see
Filing a Support Request in Customer Connect (2006985).