Release date: June 6, 2017
Profile Name | ESXi-6.0.0-20170604001-standard |
Build | For build information, see KB 2149954. |
Vendor | VMware, Inc. |
Release Date | June 6, 2017 |
Acceptance Level | PartnerSupported |
Affected Hardware | N/A |
Affected Software | N/A |
Affected VIBs | VMware_bootbank_esx-base_6.0.0-3.69.5572656 VMware_bootbank_vsan_6.0.0-3.69.5568629 VMware_bootbank_vsanhealth_6.0.0-3000000.3.0.3.69.5572665 VMware_bootbank_ehci-ehci-hcd_1.0-4vmw.600.3.69.5572656 VMware_bootbank_misc-drivers_6.0.0-3.69.5572656 VMware_bootbank_xhci-xhci_1.0-3vmw.600.3.69.5572656 VMware_bootbank_esx-ui_1.19.0-5387100 |
PRs Fixed | 1394451, 1410026, 1458558, 1664328, 1665732, 1668042, 1693612, 1701193, 1719837, 1742050, 1759902, 1765482, 1768322, 1769030, 1776387, 1777480, 1789705, 1790760, 1793825, 1794229, 1795756, 1795898, 1796950, 1797808, 1798708, 1799234, 1799321, 1799532, 1800279, 1800710, 1802377, 1804891, 1805516, 1806868, 1807032, 1807049, 1808533, 1809707, 1811355, 1823083, 1825991, 1827677, 1829156, 1830129, 1832833, 1832953, 1834405, 1835945, 1838497, 1843748, 1848150, 1848283, 1851131, 1822118, 1838537, 1790630, 1434443, 1801457, 1804667, 1832410, 1841523, 1843319, 1843969, 1848854, 1850816, 1856312, 1847505 |
Related CVE numbers | N/A |
Workaround: Resolved.
You can see the following errors in the /var/log/vmkernel.log file:
2016-11-30T21:01:56.788Z cpu0:136101)VSCSI: 273: handle 8194(vscsi0:0):Input values: res=0 limit=-2 bw=-1 Shares=1000
2016-11-30T21:01:56.788Z cpu0:136101)ScsiSched: 2760: Invalid Bandwidth Cap Configuration
2016-11-30T21:01:56.788Z cpu0:136101)WARNING: VSCSI: 337: handle 8194(vscsi0:0):Failed to invert policy.
PanicvPanicInt@vmkernel#nover+0x36b stack: 0x417ff6af0980, 0x4180368
2015-04-20T16:27:38.399Z cpu7:1000015002)0x439124d1a780:[0x4180368ad6b7]Panic_vPanic@vmkernel#nover+0x23 stack: 0x46a, 0x4180368d7bc1, 0x43a
2015-04-20T16:27:38.411Z cpu7:1000015002)0x439124d1a7a0:[0x4180368d7bc1]vmk_PanicWithModuleID@vmkernel#nover+0x41 stack: 0x439124d1a800, 0x4
2015-04-20T16:27:38.423Z cpu7:1000015002)0x439124d1a800:[0x418037cc6d46]SSDLOG_FreeLogEntry@LSOMCommon#1+0xb6e stack: 0x6, 0x4180368dd0f4, 0
2015-04-20T16:27:38.435Z cpu7:1000015002)0x439124d1a880:[0x418037d3c351][email protected]#0.0.0.1+0x849 stack: 0x46a7500, 0
Partition: 914: Read of GPT header (hdrlba = 1) failed on "naa.55cd2e404c185332" : I/O error
This results in a failure of the vSAN host when decommissioning.
None beyond the required patch bundles and reboot information listed in the table above.
An ESXi system can be updated using the image profile, by using the esxcli software profile command. For details, see the vSphere Command-Line Interface Concepts and Examples and the VMware vSphere Upgrade Guide. ESXi hosts can also be updated by manually downloading the patch ZIP file from the Patch Manager Download Portal and installing the VIB by using the esxcli software vib command.