There are two methods used to obtain the multipath information from the ESX host:
- ESXi command line – use the command line to obtain the multipath information when performing troubleshooting procedures.
- vSphere Client/vSphere Web Client – use this option when you are performing system maintenance.
ESXi Command line
To obtain LUN multipathing information from the ESXi host command line:
- Log in to the ESXi host console.
-
Type esxcli storage core path list to get detailed information regarding the paths.
For example:
fc.5001438005685fb7:5001438005685fb6-fc.5006048c536915af:5006048c536915af-naa.60060480000290301014533030303130
UID: fc.5001438005685fb7:5001438005685fb6-fc.5006048c536915af:5006048c536915af-naa.60060480000290301014533030303130
Runtime Name: vmhba1:C0:T0:L0
Device: naa.60060480000290301014533030303130
Device Display Name: EMC Fibre Channel Disk (naa.60060480000290301014533030303130)
Adapter: vmhba1
Channel: 0
Target: 0
LUN: 0
Plugin: NMP
State: active
Transport: fc
Adapter Identifier: fc.5001438005685fb7:5001438005685fb6
Target Identifier: fc.5006048c536915af:5006048c536915af
Adapter Transport Details: WWNN: xx:xx:xx:xx:xx:xx:xx:xx WWPN: xx:xx:xx:xx:xx:xx:xx:xx
Target Transport Details: WWNN: <WWNN> WWPN: <WWPN>
-
Type esxcli storage core path list -d naaID to list the detailed information of the corresponding paths for a specific device.
- The command esxcli storage nmp device list lists the LUN multipathing information:
naa.60060480000290301014533030303130
Device Display Name: EMC Fibre Channel Disk (naa.60060480000290301014533030303130)
Storage Array Type: VMW_SATP_SYMM
Storage Array Type Device Config: SATP VMW_SATP_SYMM does not support device configuration.
Path Selection Policy: VMW_PSP_FIXED
Path Selection Policy Device Config: {preferred=vmhba0:C0:T1:L0;current=vmhba0:C0:T1:L0}
Path Selection Policy Device Custom Config:
Working Paths: vmhba0:C0:T1:L0
Notes:
vSphere Client HTML5 and Web Client
To obtain multipath settings for your storage in the HTML5 client:
- Select an ESXi host, and click in the Configure tab.
- Click in Storage Devices.
- Select a the storage device that you want to verify.
- Scroll down in the Properties tab and click in "Edit multipathing...".