book
Article ID: 323127
calendar_today
Updated On:
Environment
VMware vSphere ESXi 5.1
VMware vSphere ESXi 6.7
VMware vSphere ESXi 7.0
VMware vSphere ESXi 6.0
VMware vSphere ESXi 8.0
VMware vSphere ESXi 6.5
VMware vSphere ESXi 5.5
Resolution
Validate that each troubleshooting step below is true for your environment. Each step provides instructions or a link to a document, in order to eliminate possible causes and take corrective action as necessary. The steps are ordered in the most appropriate sequence to isolate the issue and identify the proper resolution. Do not skip a step.
To troubleshoot connectivity issues to the fiber channel storage array:
- Verify that none of the hosts can see any targets in a shared storage environment. For more information, see Obtaining LUN pathing information for ESXi hosts (1003973) and Identifying Fibre Channel, iSCSi, and NFS issues on ESX/ESXi hosts(1003659).
- Verify that a rescan does not restore visibility to all the targets or brings all the LUNs back. For more information, see Performing a rescan of the storage on an ESXi host (1003988).
- Verify the connectivity to the LUNs. For more information, see Troubleshooting LUN connectivity issues (1003955).
- Verify that the fibre switch zoning configuration permits the ESXi host to see the storage array. Consult your switch vendor if you require assistance.
- Verify that the fibre switch propagates RSCN messages to the ESXi hosts.
-
-
Verify that the initiator is registered on the array, and that the storage array is configured correctly. You may need to contact your storage vendor for instructions on this procedure. For more information, see the Fibre Channel SAN Configuration Guide for your version of ESX/ESXi.
-
Verify the physical hardware:
-
The storage processors on the array.
-
The fibre switch and the Gigabit Interface Converter (GBIC) units in the switch.
-
The fibre cables between the fibre switch and the array.
-
The array itself.
Partner with the hardware vendor to ensure that the array is properly configured.
Notes:
- A rescan is required after any change is made to see if the targets are detected.
- If your problem still exists after trying the steps in this article:
-
-
File a support request with VMware Support and note this Knowledge Base article ID (1003680) in the problem description. For more information, see How to File a Support Request.