vMotion fails with the error: Migration to host failed with error timeout (0xbad0020)
search cancel

vMotion fails with the error: Migration to host failed with error timeout (0xbad0020)

book

Article ID: 335114

calendar_today

Updated On:

Products

VMware vCenter Server

Issue/Introduction

  • vMotion fails
  • The vpxd log file contains the error:

    Migration to host failed with error timeout (0xbad0020)
    [MIGRATE] (2754482182) error while tracking VMotion progress (Timedout)


Environment

VMware VirtualCenter 2.0.x

Resolution

If this issue occurs, check the following ESX vSwitch VLAN settings:
  • Ensure you are using the correct VLAN mode (EST or VST).
  • If the physical switch is set to access port, ensure that the vMotion vSwitch VLAN ID is set to 0.
  • If the physical switch is set to trunk mode, ensure that the proper VLAN ID is set on vMotion vSwitch.
  • Utilize vSwitch CDP information to assess physical switch configuration.
When the settings are correct, retry the vMotion operation.
For more information on vMotion failure, see Diagnosing VMware vMotion failure at 10% (1003734).