VMware ESXi 5.0, Patch ESXi500-201209101-SG: Updates esx-base (2032596)
Details
Release date: September 27, 2012
| Patch Category | Security |
| Patch Severity | Important |
| Build | For build information, see KB 2032584. |
| Host Reboot Required | Yes |
| Virtual Machine Migration or Shutdown Required | Yes |
| Affected Hardware | N/A |
| Affected Software | N/A |
| VIBs Included | VMware:esx-base:5.0.0-1.21.822948 |
| PRs Fixed | 783359 |
| Related CVE numbers | NA |
Solution
This patch updates the esx-base VIB to resolve an issue that occurs when you enable BPDU (Bridge Protocol Data Unit) guard on the physical switch port. The BPDU frames sent from the bridged virtual NIC cause the physical uplink to get disabled and as a result, the uplink goes down.
Note: Identify the host which sent out the BPDU packets and set esxcfg-advcfg -s 1 /Net/BlockGuestBPDU on that host. This filters out and blocks BPDU packets from the Guest. The virtual machines with the bridged virtual NICs should be powered on only after this filter is turned on for the filter to take effect.
Patch Download and Installation
The typical way to apply patches to ESXi hosts is through the VMware Update Manager. For details, see the Installing and Administering VMware vSphere Update Manager.