Knowledge Base
The VMware Knowledge Base provides support solutions, error messages and troubleshooting guides

|
Failover stops with the error, The parameter is incorrect. (87), during storage preparation on some or all LUNs (2018597)
Symptoms
- SRM test and real failovers stop during storage preparation
- You receive this error:
Failed to create snapshots of replica devices for group 'protection-group-999' using array pair 'array-pair-999': Vmacore::SystemException "The parameter is incorrect. " (87)
- The error occurs before the rescan step. However, if you manually rescan your storage from the ESX host you see that the LUN has been created and presented successfully.
Cause
<Time>0001-01-01T00:00:00</Time>
All timestamps earlier than January 1 1970 experience this issue.
Resolution
If you encounter this issue, check with your SRA vendor for a fix. As a workaround you can change the time zone of your storage.
At the time of writing, GMT and UTC are handled correctly, but Central European summer time (CEST) is not.
Impact/Risks
Request a Product Feature
To request a new product feature or to provide feedback on a VMware product, please visit the Request a Product Feature page.